微杏论坛地址入口2019

Welcome to the official website of Jiangsu Xingguang Power Generation Equipment Co., Ltd. (Shandong Xingguang Generator)!
  • After sales service
  • Contact Us |
  • Add to Favorites |
  • Online Customer Service |
Location: Home - Products
Perkins generator set series

Perkins generator set series

Release time: 2018-01-24

Phone: 18815316699
product description

Product advantages of Perkins generator set:

1. Excellent shock absorption performance: Optimal design of shock absorption system based on computer dynamic simulation.

2. Advanced control system: The control strategy of the full monitoring system based on reliability design.

3. Green environmental protection: Diesel generator set with energy saving and low emission in one.

4, low noise: tailor-made exhaust silencer system for each unit.

5. Excellent performance: stable operation, low vibration, low fuel consumption and oil consumption, long operating life, long overhaul time and low noise.

Background of Perkins

British Perkins (Perkins) Engine Co., Ltd. is a world-renowned engine manufacturer with a long history. So far, it has provided 15 million sets of power units from 4KW to 1940KW for the world; it currently has 3 production bases with an annual output of 400,000 units; the company has set up two parts release centers in Manchester and Singapore, It also has more than 3,500 service outlets around the world to provide customers around the world with uninterrupted service throughout the year. As a globally renowned Rolls-Royce manufacturer, Perkins is committed to product quality, environment and economy. Strict implementation of ISO9001, ISO14001 standards, the product has high emission standards, high economy, high stability, high reliability and other characteristics. 帕金斯发电机组

Performance of Perkins generator set

1. Electrical performance of Perkins generator set:

1) Comply with GB2820 and ISO8528 / 3 standards. And in line with the post and telecommunications system YD / T502 communication special diesel generator set technical requirements.

2) Rated voltage: 400 / 230V

3) Wiring mode: 3 phases and 4 wires

4) Frequency: 50Hz

5) Rated power factor: 0.8 (lag)

6) Suppression of radio interference: in accordance with VDE0875-N and GB2820 regulations

2. Perkins generator set standards:

1) Meet the requirements of GB / T2819, ISO8528, IEC34 and other international standards;

2) The rated output power of the generator set complies;

3) The altitude does not exceed 1000 meters;

4) Ambient temperature is 0 ℃ ~ 40 ℃;

5) Air relative humidity 60%;

3. Alternator of Perkins generator set:

1) Excitation method: brushless self-excitation

2) Insulation class: H class

3) Protection level: IP21 ~ IP23

4) Voltage adjustment: automatic adjustment

4. Control box of Perkins generator set:

There are different types of control boxes such as manual, automatic, remote monitoring, and full-automatic intelligence. Basic configuration includes voltmeter, ammeter, water temperature gauge, oil pressure gauge, controller, emergency stop button, preheat button, battery voltmeter, timetable, phase selection switch, etc.

 

Fourth, the principle of Perkins generator set

In the diesel engine cylinder, the clean air filtered by the air filter is fully mixed with the high-pressure atomized diesel injected by the fuel injection nozzle. Under the squeeze of the piston upward, the volume is reduced, and the temperature is rapidly increased to reach the ignition point of the diesel. Diesel is ignited, the mixed gas burns violently, and the volume expands rapidly, pushing the piston downward, which is called 'work'. Each cylinder works in a certain order, and the thrust on the piston passes through the connecting rod and becomes the force that drives the crankshaft to rotate, thereby driving the crankshaft to rotate. By installing the brushless synchronous alternator coaxially with the crankshaft of the diesel engine, the rotor of the generator can be driven by the rotation of the diesel engine. Using the principle of "electromagnetic induction", the generator will output the induced electromotive force, and the current can be generated through the closed load circuit. .

V. Maintenance of Perkins generators

1) After 60 hours of operation of the diesel generator, you need to change the oil, clean the diesel filter, and air filter.

2) The electrolyte of the battery should be checked frequently and replenished in time when it is insufficient.

3) The tension of the belt should be checked frequently, and the tension mechanism should be adjusted to maintain the tension.

4) The water heating and oil heating switches should be turned on in cold seasons to keep the unit at a certain temperature to ensure the normal use of the diesel generator set.

6. Appearance requirements of Perkins generator set:

1) The limit size, installation size and connection size of the diesel generator set conform to the factory drawings approved by the prescribed procedures

2) The welding of the unit should be firm, the welds should be uniform, no welding penetration, undercuts, slag inclusions and pores and other defects, the slag welding flux should be removed; the paint film should be uniform without obvious cracks and peeling; the coating should be smooth, No missing plating spots, rust and other phenomena; unit fasteners should not be loose.

3) The electrical installation of the diesel generator set should comply with the circuit diagram, and there should be obvious signs that the lead wires of the unit are not easy to fall off.

4) Diesel generator sets should have well-grounded terminals.

5) The content of the diesel generator set is complete.

The technical parameters of Perkins generator are as follows:

Unit Type

Output Power

(KW / KVA)

Diesel engine model

generator

model

Rated speed

(R / min)

Rated current

(A)

Dimensions

L × W × H (mm)

Unit weight

(Kg)

XG-10GF

10 / 12.5

403C-15G

STC-10

1500

18

1400 × 477 × 840

350

XG-15GF

15 / 18.75

404C-22G

STC-15

1500

27

1450 × 477 × 840

380

XG-20GF

20/25

1103A-33G

STC-20

1500

36

1650 × 850 × 1250

850

XG-30GF

30 / 37.5

1103A-33TG1

STC-30

1500

54

1720 × 850 × 1250

850

XG-50GF

50 / 62.5

1104A-44TG1

TFW2-50

1500

90

2050 × 630 × 1150

1000

XG-75GF

75 / 93.75

1104C-44TG1

TFW2-75

1500

135

2100 × 752 × 1300

900

XG-100GF

100/125

1104C-44TG2

TFW2-100

1500

180

2300 × 752 × 1300

1100

XG-120GF

120/150

1006TAG2

TFW2-120

1500

216

2630 × 780 × 1370

1360

XG-150GF

150 / 187.5

1106C-E66TAG4

TFW2-150

1500

270

2800 × 900 × 1400

1500

XG-200GF

200/250

1306C-E87TAG6

TFW2-200

1500

360

2870 × 900 × 1650

2350

XG-300GF

300/375

2206C-E13TAG2

TFW2-300

1500

540

3150 × 950 × 1900

2400

XG-350GF

350 / 437.5

2306A-E15TAG1

TFW2-350

1500

630

3300 × 1150 × 1950

3200

XG-400GF

400/500

2506A-E15TAG2

TFW2-400

1500

720

3300 × 1150 × 1950

3200

XG-500GF

500/625

2806A-E18TAG1

TFW2-500

1500

900

3300 × 1500 × 2100

3800

XG-640GF

640/800

4006-23TAG2A

TFW2-640

1500

1152

4100 × 1700 × 2100

5800

XG-800GF

800/1000

4008TAG2A

TFW2-800

1500

1440

4960 × 1990 × 2300

7200

XG-1000GF

1000/1250

4012-46TWG2A

TFW2-1000

1500

1800

5300 × 2190 × 2450

9400

XG-1200GF

1200/1500

4012-46TAG2A

TFW2-1200

1500

2160

5200 × 2240 × 2550

11500

XG-1500GF

1500/1875

4016TAG1A

TFW2-1500

1500

2700

6800 × 2780 × 3500

12000

XG-1600GF

1600/2000

4016TAG2

TFW2-1600

1500

2880

6800 × 2780 × 3500

12500


( Note: if the above parameter configuration table is not exhaustive, please consult online customer service)



Jiangsu Xingguang Power Generation Equipment Co., Ltd. (Shandong Xingguang Generator)

Address: Headquarters: No. 2 Xingguang Road, Guxi Town, Taixing City, Jiangsu Province Branch: 3-1-2301, Hengda Yayuan, Qingdao West Road, Yinan District, Jinan City, Shandong Province

Phone: 18815316699

Record number: Su ICP No. 13060714

Technical Support: Jingchuang Network