  • The installation of smoke exhaust pipe of diesel generator set should pay attention that the exposed part of the smoke exhaust pipe is not in contact with wood or other flammable substances, and can prevent the infiltration of rainwater, and its extension can also allow thermal expansion. In this article, Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer, will share the two laying methods and relevant precautions of the diesel generator smoke exhaust pipe. method one……

  • I have already introduced the relevant operation steps of A and B maintenance for diesel generator sets. So how to do C-class maintenance for generators? This article is briefly introduced by Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer. The C-class maintenance of the diesel generator set must first repeat the A- and B-class maintenance work mentioned above, and then the following maintenance needs to be done: 1) ...

  • Class A maintenance for diesel generator sets includes: checking the oil level and coolant level of the generator, checking the air filter, cleaning the air filter core, starting the generator and checking for abnormal noise, etc. Machine manufacturer--Jiangsu Xingguang Power Generation Equipment Co., Ltd. will introduce them one by one. 1) Check the generator daily report. 2) Check the generator oil level, ...

  • In the last part, I have shared the A-class maintenance methods for diesel generators. So what kind of work is required for B-class maintenance of diesel generators? This article continues to be briefly introduced by Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer. 1) Repeat A-level daily inspection. 2) Every 100 to 250 hours, the diesel filter should be replaced. All diesel filters are not washable ...

  • Shandong supply Jiangsu Cummins series diesel generator set manufacturers Diesel generator incorrect operation one: The diesel engine runs when the engine oil is insufficient. At this time, the insufficient oil supply to the friction surfaces due to insufficient engine oil supply will cause abnormal wear or burn. For this reason, before the start of the diesel generator and during the operation of the diesel engine, ensure that the engine oil is sufficient to prevent cylinder failure and tile burning failure due to lack of oil. Diesel generator error ...

  • Cummins Dongfeng Series 200kw diesel generator set factory direct automatic voltage regulator (AVR) enables the main generator to maintain a stable voltage from no-load operation to full-load operation. The main stator provides power to the exciter's magnetic field through the AVR, and can automatically adjust the exciter's magnetic field current. ATR.AVR feedbacks the voltage induction signal from the stator winding of the host. By controlling the magnetic field of the low power exciter, you can adjust ...

  • 300KW Dongfeng Cummins (Starlight) Series Diesel Generator Set 300KW Cummins Series Diesel Generator Set Technical Specifications Diesel Generator Set Technical Parameters: Unit Model: Lc -300GF Steady-state Voltage Regulation Rate (%): ≤ ± 1 Common Power: 300Kw Voltage Fluctuation Rate (%): ≤ ± 0.5 ...

  • The design of each diesel generator set has a certain power range. At the same time, there is a certain gap in power between the diesel engine and the alternator. Their design prevents the diesel generator from exceeding a certain power value. When the power is exceeded, the diesel engine cannot provide power or excessive power causes damage to the engine. It is therefore important to distinguish between common power and standby power. below……

  • Diesel generators have the advantages of long life, low fuel consumption, strong power, long-term continuous use, and emergency standby power. They are widely used in ships, defense, communications, petroleum, mining, field rescue, agriculture and other fields. So after operating the electrician to take over the diesel generator set, which three points should be checked first? This article is a professional diesel generator manufacturer--Jiangsu Xingguang Power Generation Equipment Co., Ltd ....

  • The capacity of the emergency diesel generator should meet the needs of both the fire load and the load to ensure a stable calculation of the load. When there are multiple generator sets in standby, generally only one emergency diesel generator set is provided, and two units can also be selected for reliability Supply power in parallel. This article introduces the emergency diesel generator sets by professional diesel generator manufacturers--Jiangsu Xingguang Power Generation Equipment Co., Ltd ...

  • The insulation level of a generator is determined by the heat resistance level of the insulation material it uses. If the insulation structure of the main parts of a motor is made of insulation materials with different heat resistance grades, the insulation grades are evaluated according to the minimum heat resistance grade of the insulation materials. There is no difference between the insulation level of the generator, and it depends on the application. This article is from a professional diesel generator manufacturer--Jiangsu Xingguang Power Generation Equipment Co., Ltd. for ...

  • The capacity of the emergency diesel generator should meet the needs of both the fire load and the load to ensure a stable calculation of the load. When there are multiple generator sets in standby, generally only one emergency diesel generator set is provided, and two units can also be selected for reliability Supply power in parallel. This article introduces the capacity of emergency diesel generator sets by Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer ...

  • Cummins generator | Cummins 400KW generator parameters Cummins generator / generator installation 1, Cummins generator room design 1) The unit should be arranged horizontally, when it is limited by the building site, it can be arranged vertically 2) When the machine room is adjacent to the control room The generator outlet and cable trench should be close to the power distribution room. ...

  • The design of each diesel generator set has a certain power range. At the same time, there is a certain gap in power between the diesel engine and the alternator. Their design prevents the diesel generator from exceeding a certain power value. When the power is exceeded, the diesel engine cannot provide power or excessive power causes damage to the engine. It is therefore important to distinguish between common power and standby power. below……

  • Lead-acid batteries commonly used in diesel generator sets are mainly divided into two categories, namely dry-charge batteries and maintenance-free batteries. This article is briefly introduced by Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer. I. Dry-charged battery: Its full name is dry-charged lead-acid battery. Its main feature is that the negative plate has a high power storage capacity. In a completely dry state, it can ...

  • The “speeding” of a diesel generator set means that the speed of the diesel engine is out of control and greatly exceeds the specified maximum speed. When the user is facing the “speeding” failure phenomenon, [http://taoyoupub.cn Jiangsu Starlight Power Equipment Co., Ltd. Shandong Sales Center] should analyze from the fuel supply system, excessive fuel supply, and high-speed governor limit Changes in screws, etc. can cause a sharp increase in speed. due to"……

  • What aspects of the diesel generator room environmental protection project include? When the diesel generator set is running, the black smoke and sulfur dioxide of the exhaust gas are inevitable, and the noise of the engine room is still above 98dB (A). If left untreated, the high decibel noise and black smoke emitted will cause pollution to the surrounding environment. According to the requirements of the environmental protection department, the diesel generator room needs to be environmentally treated, mainly including the following workers ...

  • Diesel generator sets should be inspected in the construction site, so that the generator can be prevented from delaying construction due to faults, and the power supply of the project is stable. In this article, Jiangsu Xingguang Power Generation Equipment Co., Ltd., a professional diesel generator manufacturer, will learn the five major inspections of diesel generators at construction sites with everyone. [http://taoyoupub.cn Jiangsu Xingguang Power Generation Equipment Limited ...

  • When one of the following conditions occurs in a diesel generator set, an emergency stop must be performed. At this time, the load should be cut off, and the fuel injection pump switch handle should be immediately turned to the position to cut off the oil circuit, so that the diesel engine will immediately stop; the unit pressure gauge value drops below the specified value. In this article, a professional diesel generator manufacturer--Jiangsu Xingguang Power Generation Equipment Co., Ltd. will learn the correct operation of emergency shutdown of a diesel generator ...

  • The maintenance level of diesel generator sets includes W1 general inspection and operation inspection, W2 and W3 regular maintenance, W4 unit intermediate repair, W5 unit overhaul, etc. So what are its main contents? This article is introduced by the professional diesel generator manufacturer-Jiangsu Xingguang Power Generation Equipment Co., Ltd. W1 (daily general inspection and inspection for 30 minutes of operation) inspection: whether the unit has loose screws, check for three leaks, machine ...